Application |
GV series motor protection circuit breakers are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network |
Specifications |
|
Rated standard power of 3-phase motors 50/60Hz in category AC-3 |
Setting range (A |
220V |
380V |
415V |
440V |
500V |
660V |
KW |
KW |
KW |
KW |
KW |
KW |
GV2ME01 |
-- |
-- |
-- |
-- |
-- |
-- |
0.1-0.16 |
GV2ME02 |
-- |
-- |
-- |
-- |
-- |
-- |
0.16-0.25 |
GV2ME03 |
-- |
-- |
-- |
-- |
-- |
-- |
0.25-0.4 |
GV2ME04 |
-- |
-- |
-- |
-- |
-- |
0.37 |
0.4-0.63 |
GV2ME05 |
-- |
-- |
-- |
0.37 |
0.37 |
0.55 |
0.63-1 |
GV2ME06 |
-- |
0.37 |
-- |
0.55 |
0.75 |
1.1 |
1-1.6 |
GV2ME07 |
0.37 |
0.75 |
0.75 |
1.1 |
1.1 |
1.5 |
1.6-2.5 |
GV2ME08 |
0.75 |
1.5 |
1.5 |
1.5 |
2.2 |
3 |
2.5-4 |
GV2ME10 |
1.1 |
2.2 |
2.2 |
3 |
3.7 |
4 |
4-6.3 |
GV2ME14 |
2.2 |
4. |
4 |
4 |
5.5 |
7.5 |
6-10 |
GV2ME16 |
3 |
5.5 |
5.5 |
7.5 |
7.5 |
9 |
9-14 |
GV2ME20 |
4 |
7.5 |
9 |
9 |
9. |
11 |
13-18 |
GV2ME21 |
5.5 |
11 |
11 |
11 |
11 |
15 |
17-23 |
GV2ME22 |
5.5 |
11 |
11 |
11 |
15 |
18.5 |
20-25 |
GV2ME32 |
7.5 |
15 |
15 |
15 |
18.5 |
26 |
24-32 |
GV3ME06 |
-- |
0.37 |
-- |
0.55 |
0.75 |
1.1 |
1-1.6 |
GV3ME07 |
0.37 |
0.75 |
1.1 |
1.1 |
1.1 |
1.5 |
1.6-2.5 |
GV3ME08 |
0.75 |
1.5 |
1.5 |
1.5 |
2.2 |
3 |
2.5-4 |
GV3ME10 |
1.1 |
2.2 |
2.2 |
3 |
3.7 |
4 |
4-6 |
GV3ME14 |
2.2 |
4 |
4 |
4 |
5.5 |
7.5 |
6-10 |
GV3ME20 |
4 |
7.5 |
7.5 |
7.5 |
10 |
11 |
10-16 |
GV3ME25 |
5.5 |
11 |
11 |
11 |
15 |
18.5 |
16-25 |
GV3ME40 |
11 |
18.5 |
22 |
22 |
25 |
33 |
25-40 |
GV3ME63 |
15 |
30 |
33 |
33 |
40 |
55 |
40-63 |
GV3ME80 |
22 |
40 |
45 |
45 |
55 |
63 |
56-80 |
PKZMO Motor Protective Circuit Breaker Is Applicable For The Circuit Of Ac 50/60Hz,Rated Insulation Voltage 750V,Rated Operating Voltage Up To 660V,Rated Operating Current From 0.1A To 25A,It Is Used For Protecting The Motor Against Overload,Short-Circuit And Phase-Failure.It Can Be Also Used For Starting And Breaking The Starter Of Motor And For The Circuit Protection In The Circuit Of 25A
Specifications
Power of controlled motor
400V P KW |
Rated operating current
400V le A |
Range of overload tripping current
lr A |
Switching capacity
400V lq kA |
- |
0.16 |
0.1-0.16 |
100 |
0.06 |
0.25 |
0.16-0.25 |
100 |
0.09 |
0.40 |
0.25-0.4 |
100 |
0.12 |
0.63 |
0.4-0.63 |
100 |
0.25 |
1.00 |
0.63-1 |
100 |
0.55 |
1.60 |
1-1.6 |
100 |
0.75 |
2.50 |
1.6-2.5 |
100 |
1.50 |
4.00 |
2.5-4 |
100 |
2.2 |
6.3 |
4-6.3 |
100 |
3 |
6.6 |
6.3-10 |
100 |
4 |
10 |
6.3-10 |
100 |
5.5 |
16 |
10-16 |
100 |
7.5 |
16 |
10-16 |
100 |
9 |
20 |
16-20 |
100 |
12.5 |
25 |
20-25 |
100 |
| |